Zone Feature Programming
Zone Feature Programming can be used to set all the different combinations of alarm
modes.
Simply put the corresponding zones dipswitch up, and press the tamper to change the
features. For every press of the tamper, the feature will increment to the next, the number of
beep(s) heard correspond to the feature that you have activated:
ZONE FEATURE PROGRAMMING
1.
Set the dipswitch for the zone you wish to program.
2.
Press the tamper until the desired feature is reached.
For every press of the tamper, the feature will increment
to the next, the number of beep(s) heard correspond to
the feature that you have activated.
Beeps
Alarm Mode
1
Zone is always active when system is armed
2
Not used
3
Zone is now only active in away mode, disable in home mode
4
Zone is now only 24 hour zone
5
Zone is always active when system is armed with a 30 second entry delay
6
Not used
7
Zone is now active in away only with 30 second entry delay, disable in home
mode
TAMPER